Vitals Fitness Band
Keywords:
Alert, Body temperature, Firmware, Fitness and wellness, Heart rate measurement, MAX30102 sensor, Medical, NRF connect for mobile app, Photoplethysmography (PPG), Real-time, Remote patient monitoring, SpO₂ monitoring, TTGO ESP32, Vitals fitness, WearableAbstract
The vitals fitness band is a technologically advanced wearable health monitor for real-time recording of vital signs such as blood oxygen saturation (SpO₂), pulse rate, and body temperature. It employs the TTGO ESP32 microcontroller and the MAX30102 biosensor, which employ Photoplethysmography (PPG) technology for providing secure and power-saving monitoring. The device can easily be integrated with smartphones using Bluetooth Low Energy (BLE) and supports the nRF Connect for Mobile app, which enables real-time data transfer and historical health analysis. One of the strongest aspects of the Vitals Fitness Band is its emergency alert system that alerts caregivers and patients through alarms in case of SpO₂ below 90%, blood pressure below 40 mmHg or above 120 mmHg, or body temperature outside the usual range of 36.1 to 37.5°C. The alarms are both on the device and the mobile app, allowing quick intervention. Additionally, the application also supports secure medical data sharing with family members, doctors, or caregivers for remote monitoring of the patient and individualized health care management. Being a fitness expert and a general health monitoring application, Vitals fitness band is a cost-effective preventive care solution, supported by IoT functionalities for greater real-time observation, emergency help, and proactive prevention of ailments.
References
K. D. Torp, P. Modi, E. J. Pollard, and L. V. Simon, “Pulse oximetry,” Journal of Clinical Monitoring and Computing, vol. 37, pp. 115–122, July 30, 2023. https://pubmed.ncbi.nlm.nih.gov/29262014/
G. Sidhartha, “IoT based pulse oximeter,” International Journal for Research in Applied Science and Engineering Technology, vol. 9, no. 8, pp. 2946–2951, Aug. 2021, doi: https://doi.org/10.22214/ijraset.2021.37782
K. V. S. S. Ganesh, S. P. S. Jeyanth, and A. R. Bevi, “IOT based portable heart rate and SpO2 pulse oximeter,” HardwareX, vol. 11, p. e00309, Apr. 2022, doi: https://doi.org/10.1016/j.ohx.2022.e00309
L. J. Herbert and I. H. Wilson, “Pulse oximetry in low-resource settings,” Breathe, vol. 9, no. 2, pp. 90–98, Dec. 2012, doi: https://doi.org/10.1183/20734735.038612
A. M. Cabanas, M. Fuentes-Guajardo, K. Latorre, D. León, and P. Martín-Escudero, “Skin pigmentation influence on pulse oximetry accuracy: A systematic review and bibliometric analysis,” Sensors, vol. 22, no. 9, p. 3402, Apr. 2022, doi: https://doi.org/10.3390/s22093402
S. Fouzas et al., “Knowledge on pulse oximetry among pediatric health care professionals: A multicenter survey,” Pediatrics, vol. 126, no. 3, pp. e657-62, Sep. 2010, doi: https://doi.org/10.1542/peds.2010-0849
C. Shi et al., “The accuracy of pulse oximetry in measuring oxygen saturation by levels of skin pigmentation: a systematic review and meta-analysis,” BMC Medicine, vol. 20, no. 1, pp. 1–14, Aug. 2022, doi: https://doi.org/10.1186/s12916-022-02452-8
Sameer Abusuwaleh, “Difference between Max30100 and Max30102 Sensor,” Regent Electronics, Jan. 24, 2025. Available: https://regentelectronics.com/sensors-modules/difference-between-max30100-and-max30102-sensor
T. Tamura, Y. Maeda, M. Sekine, and M. Yoshida, “Wearable photoplethysmographic sensors—Past and present,” Electronics, vol. 3, no. 2, pp. 282–302, Jun. 2014, doi: https://doi.org/10.3390/electronics3020282
M. Elgendi, “On the analysis of fingertip photoplethysmogram signals,” Current Cardiology Reviews, vol. 8, no. 1, pp. 14–25, Jun. 2012, doi: https://doi.org/10.2174/157340312801215782
A. Gaddam, S. C. Mukhopadhyay, and G. S. Gupta, Wireless sensors and networks for healthcare applications. Springer, 2015.
Espressif Systems, “ESP32 Technical Reference Manual, Version 4.7, 2023,” Available: https://www.espressif.com/sites/default/files/documentation/esp32_technical_reference_manual_en.pdf
Espressif Systems, “ESP-IDF programming guide,” Available: https://docs.espressif.com/projects/esp-idf/en/latest/esp32/
Maxim Integrated, “MAX30102 pulse oximeter and heart-rate sensor for wearable health,” Datasheet, 2022. Available: https://datasheets.maximintegrated.com/en/ds/MAX30102.pdf
SparkFun Electronics, “SparkFun MAX3010x pulse oximeter sensor library (MAX30105.h),” GitHub, 2021. Available: https://github.com/sparkfun/SparkFun_MAX3010x_Sensor_Library